Validity and reliability of the Modified Four Square Step Test in individuals with ankle sprain

dc.contributor.authorYetis, Mehmet
dc.contributor.authorKocaman, Hikmet
dc.contributor.authorCanli, Mehmet
dc.contributor.authorAlkan, Halil
dc.contributor.authorYildirim, Hasan
dc.contributor.authorYildiz, Nazim Tolgahan
dc.contributor.authorKuzu, Safak
dc.date.accessioned2024-12-14T22:07:27Z
dc.date.available2024-12-14T22:07:27Z
dc.date.issued2024
dc.departmentMuş Alparslan Üniversitesien_US
dc.description.abstractBackground Postural instability and gait abnormalities are frequently observed after an ankle sprain. A modified Four Square Step Test (mFSST) was developed to assess dynamic balance during gait. The aim of this study was to evaluate the reliability and validity of the mFSST in individuals with ankle sprains. Methods The study included 39 individuals with grade 1 and 2 ankle sprains with a mean age of 30.36 +/- 6.21 years. The dynamic balance of the participants was assessed with the mFSST and Timed Up & Go test (TUG). To determine the test-retest reliability of the mFSST, the test was repeated approximately 1 h apart. Results The test-retest reliability of the mFSST was excellent (ICC = 0.85). Furthermore, when the concurrent validity of the mFSST was examined, a high correlation was found between with the TUG (r = 0.78, p < 0.001). Conclusion The mFSST is a valid and reliable clinical assessment method for evaluating dynamic balance during walking in individuals with ankle sprains. We think that the mFSST is preferable in clinical evaluations because its platform is easy to prepare and requires very little equipment.en_US
dc.identifier.doi10.1186/s13018-024-04664-5
dc.identifier.issn1749-799X
dc.identifier.issue1en_US
dc.identifier.orcid0000-0002-8868-9599
dc.identifier.orcidYILDIZ, Nazim Tolgahan
dc.identifier.orcid0000-0002-2404-2884
dc.identifier.orcid0000-0001-6895-2495
dc.identifier.orcid0000-0003-4582-9018
dc.identifier.orcid0000-0001-5971-7274
dc.identifier.orcid0000-0003-0145-3565
dc.identifier.pmid38491530
dc.identifier.scopus2-s2.0-85187900554
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1186/s13018-024-04664-5
dc.identifier.urihttps://hdl.handle.net/20.500.12639/6622
dc.identifier.volume19en_US
dc.identifier.wosWOS:001185882000001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherBmcen_US
dc.relation.ispartofJournal of Orthopaedic Surgery and Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmzKA_20241214
dc.subjectAnkle sprainen_US
dc.subjectModified Four Square Step Testen_US
dc.subjectValidityen_US
dc.subjectReliabilityen_US
dc.titleValidity and reliability of the Modified Four Square Step Test in individuals with ankle sprainen_US
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
6622.pdf
Boyut:
1.22 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text