Biomechanical investigation of osseointegration of loosely and overtightly placed titanium implants
Yükleniyor...
Tarih
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Univ Zulia, Facultad Ciencias Veterinarias
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
The objective of this research was to biomechanically assess the osseointegration of implants placed in bone sites prepared with diameters smaller than, larger than, or equal to the implant weighing between 250-300 g were used in the study. The rats were divided into three groups and titanium implants, 2.5 mm diameter and 4 mm lenght, were placed in the cortico-cancellous bone structure in the metaphyseal parts of the right tibia bones of all rats included in the study. The study groups were; the group in which a bone bed of 2.2 mm in diameter and 4 mm in length was prepared and the implants were placed very tightly (n=7), the group in which a bone bed of 2.8 mm in diameter and 4 mm in
Açıklama
Anahtar Kelimeler
Bone Implantation, Biomechanical Measurement
Kaynak
Revista Cientifica-Facultad de Ciencias Veterinarias
WoS Q Değeri
Scopus Q Değeri
Cilt
35
Sayı
3