Fabrication and Experimental Study of Micro-gripper with Electrothermal Actuation by Stereolithography Method
| dc.authorscopusid | 57203010756 | |
| dc.authorscopusid | 57214723123 | |
| dc.authorscopusid | 6603831545 | |
| dc.authorscopusid | 55566641300 | |
| dc.contributor.author | Ülkir, Osman | |
| dc.contributor.author | Ertuğrul, İshak | |
| dc.contributor.author | Akkus, Nihat | |
| dc.contributor.author | Özer, Salih | |
| dc.date.accessioned | 2022-09-04T10:26:53Z | |
| dc.date.available | 2022-09-04T10:26:53Z | |
| dc.date.issued | 2022 | |
| dc.department | Meslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Elektronik ve Otomasyon Bölümü | en_US |
| dc.department | Meslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Makine ve Metal Teknolojileri Bölümü | en_US |
| dc.department | Meslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Elektronik ve Otomasyon Bölümü | en_US |
| dc.department | Meslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Makine ve Metal Teknolojileri Bölümü | en_US |
| dc.description.abstract | The aim of the study is to get high displacement values with low actuation voltage from the micro-gripper fabricated by stereolithography (SLA) method. Micro-grippers are devices based on a micro-electro-mechanical system (MEMS) preferred for manipulation and assembly in micro-fabrication. This article presents the modeling, fabrication, and experimental studies of a U-type electrothermal MEMS micro-gripper. The fabrication of the gripper was made by SLA, which is one of the additive manufacturing methods. The arm tip displacement of the gripper has been characterized in real-time by optical microscopy. In electrical characterization studies, the electrical voltage was applied to the pads of the micro-gripper. This voltage value was increased starting from 0V with 1V increments until deterioration was observed in the gripper. The micro-gripper is shown to actuate to a maximum opening displacement of 28.35 mu m at an applied voltage of 5V. The models are employed to examine key factors of the micro-gripper's performance including temperature distribution, displacement, and stresses based on an elastic analysis of structures. Experimental results for the displacement of the micro-gripper's arm tips were found to be in good agreement with the simulation results. | en_US |
| dc.identifier.doi | 10.1007/s11665-022-06875-5 | |
| dc.identifier.issn | 1059-9495 | |
| dc.identifier.issn | 1544-1024 | |
| dc.identifier.scopus | 2-s2.0-85128298059 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.uri | https://doi.org/10.1007/s11665-022-06875-5 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12639/4630 | |
| dc.identifier.wos | WOS:000783394200004 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.institutionauthor | Ülkir, Osman | |
| dc.institutionauthor | Ertuğrul, İshak | |
| dc.language.iso | en | |
| dc.publisher | Springer | en_US |
| dc.relation.ispartof | Journal Of Materials Engineering And Performance | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | additive manufacturing; electrothermal actuation; electrical characterization; MEMS; stereolithography; tip displacement | en_US |
| dc.subject | Piezoelectric Actuator; Design; Manipulation; Microgripper | en_US |
| dc.title | Fabrication and Experimental Study of Micro-gripper with Electrothermal Actuation by Stereolithography Method | en_US |
| dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 4630.pdf
- Boyut:
- 2.76 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text










