Fabrication and Experimental Study of Micro-gripper with Electrothermal Actuation by Stereolithography Method

dc.authorscopusid57203010756
dc.authorscopusid57214723123
dc.authorscopusid6603831545
dc.authorscopusid55566641300
dc.contributor.authorÜlkir, Osman
dc.contributor.authorErtuğrul, İshak
dc.contributor.authorAkkus, Nihat
dc.contributor.authorÖzer, Salih
dc.date.accessioned2022-09-04T10:26:53Z
dc.date.available2022-09-04T10:26:53Z
dc.date.issued2022
dc.departmentMeslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Elektronik ve Otomasyon Bölümüen_US
dc.departmentMeslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Makine ve Metal Teknolojileri Bölümüen_US
dc.departmentMeslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Elektronik ve Otomasyon Bölümüen_US
dc.departmentMeslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Makine ve Metal Teknolojileri Bölümüen_US
dc.description.abstractThe aim of the study is to get high displacement values with low actuation voltage from the micro-gripper fabricated by stereolithography (SLA) method. Micro-grippers are devices based on a micro-electro-mechanical system (MEMS) preferred for manipulation and assembly in micro-fabrication. This article presents the modeling, fabrication, and experimental studies of a U-type electrothermal MEMS micro-gripper. The fabrication of the gripper was made by SLA, which is one of the additive manufacturing methods. The arm tip displacement of the gripper has been characterized in real-time by optical microscopy. In electrical characterization studies, the electrical voltage was applied to the pads of the micro-gripper. This voltage value was increased starting from 0V with 1V increments until deterioration was observed in the gripper. The micro-gripper is shown to actuate to a maximum opening displacement of 28.35 mu m at an applied voltage of 5V. The models are employed to examine key factors of the micro-gripper's performance including temperature distribution, displacement, and stresses based on an elastic analysis of structures. Experimental results for the displacement of the micro-gripper's arm tips were found to be in good agreement with the simulation results.en_US
dc.identifier.doi10.1007/s11665-022-06875-5
dc.identifier.issn1059-9495
dc.identifier.issn1544-1024
dc.identifier.scopus2-s2.0-85128298059
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1007/s11665-022-06875-5
dc.identifier.urihttps://hdl.handle.net/20.500.12639/4630
dc.identifier.wosWOS:000783394200004
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorÜlkir, Osman
dc.institutionauthorErtuğrul, İshak
dc.language.isoen
dc.publisherSpringeren_US
dc.relation.ispartofJournal Of Materials Engineering And Performanceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectadditive manufacturing; electrothermal actuation; electrical characterization; MEMS; stereolithography; tip displacementen_US
dc.subjectPiezoelectric Actuator; Design; Manipulation; Microgripperen_US
dc.titleFabrication and Experimental Study of Micro-gripper with Electrothermal Actuation by Stereolithography Methoden_US
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
4630.pdf
Boyut:
2.76 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text